Magnum PT-100
Maximize Energy Harvest and Improve Battery Life
The Magnum PT 100 is a Maximum Power Point Tracker (MPPT) charge controller designed to harvest the maximum available energy from the PV array and deliver it to the batteries.
The PT 100’s MPPT algorithm finds the maximum power point of the array and operates at this point while regulating the output current and battery voltage to fully charge the battery.
Output Current
100 amps
|
Battery Voltage
12, 24, or 48 V
|
MPPT
Yes
|
Power Consumption
< 4 watts (nighttime mode)
|
Maximum PV input voltage (any condition)
200 VDC + battery voltage or 240 VDC - whichever is lower
|
Maximum PV operating voltage
187 VDC
|
Maximum PV array short circuit current
100 ADC
|
Nominal battery voltage range
12, 24, or 48 VDC
|
Battery charger output voltage range
10 to 66 VDC
|
Continuous charger output current
100 ADC (from -20°C to +40°C) with proportional power reduction up to 60°C ambient
|
Maximum output power
6600 watts
|
Peak (and full power) efficiency
>99% (98% typical)
|
Tare loss / nighttime power consumption
<2 watts (fan off, display/LEDs off)
|
Charger regulation method
Automatic three-stage (bulk, absorption, float) charge with manual equalization
|
Battery temperature compensation
With Battery Temperature Sensor (BTS) connected (battery temperature -20 °C to +55 °C)
|
Internal cooling
Using dual ball-bearing fans for long life
|
Overcurrent protection
With two overlapping circuits
|
Over-temperature protection
On transformer and MOSFETS
|
Listings
CE & ETL Listed to UL/cUL 1741, CSA C22.2 #107.1-01
|
Warranty
Five years parts and labor
|
Operating temperature
-20° C to +60° C (-4° F to 140° F)
|
Nonoperating temperature
-40° C to +70° C (-40° F to 158° F)
|
Operating humidity
0 to 95% RH non condensing
|
Enclosure type
Indoor, ventilated, with removable powder-coated conduit box
|
Unit dimensions (w x h x d)
8.5" x 15.5" x 4.0" (21.6 cm x 39.4 cm x 10.2 cm)
|
Shipping dimensions (w x h x d)
11.5” x 19.5” x 8.125” (29.2 cm x 49.5 cm x 20.6 cm)
|
Mounting
Mounted on a vertical surface (wall) or installed on MP or MMP enclosure
|
Weight
12.5 lb (5.7 kg)
|
Shipping weight
15 lb (6.8 kg)
|
Max operating altitude
15,000’ (4570 m)
|